Engineering · Mid-career

Electrical Engineer Resume Example

This example suits an electrical engineer with three to eight years of experience in power distribution, whether at a consultancy, a contractor, a utility or an equipment maker. It shows how voltage levels, fault ratings, study types and test methods make the scope of your work clear, and how to present design and commissioning side by side.

The example resume

Laid out in the Docket template. The person, employers, schools and figures in this example are invented for illustration. Any resemblance to real people or organisations is unintended.

Aisyah Hamzah

Electrical Engineer | Power Distribution, Protection Studies, Substation Commissioning

  • aisyah.hamzah@example.com
  • +1 555 0176
  • Kuala Lumpur, Malaysia
  • linkedin.example.com/in/aisyah-hamzah

Professional summary

Electrical engineer with six years of experience in medium- and low-voltage power distribution for industrial plants and solar farms. Carries a design from single-line diagram and protection study to factory testing and site commissioning, using ETAP and AutoCAD Electrical. Currently working towards professional engineer registration.

Work experience

Electrical Engineer

Meranti Grid Consultants, Kuala Lumpur

Jan 2023 – Present

  • Designed the 33 kV collector network for a 30 MWac solar farm, covering the single-line diagram, cable sizing, earthing grid and switchgear specification
  • Completed load-flow, short-circuit and protection coordination studies in ETAP for 14 industrial sites, issuing relay settings for overcurrent, earth-fault and transformer differential protection
  • Found a 400 V switchboard rated 50 kA facing a 58 kA calculated fault level at a food plant, and redesigned it for split-bus operation before energisation
  • Carried out arc-flash studies to IEEE 1584 for nine sites, relabelling 210 panels and lowering incident energy on 17 boards through revised relay settings
  • Commissioned three 11 kV substations with the testing contractor (relay secondary injection, insulation resistance, CT ratio and polarity, interlocks), each energised on its planned date

Electrical Design Engineer

Selat Switchgear Industries, Shah Alam

Aug 2020 – Dec 2022

  • Drew schematics, wiring diagrams and general arrangements in AutoCAD Electrical for more than 80 low-voltage switchboards and motor control centres rated up to 4,000 A
  • Conducted routine and factory acceptance tests in front of client inspectors, including dielectric, functional and primary-injection tests, with 94% of boards passing first time
  • Programmed and tested automatic transfer logic on Siemens S7-1200 PLCs for 12 generator-backed switchboards, replacing hard-wired relay schemes
  • Created a library of 45 standard circuit templates, shortening drawing time for a typical motor control centre from five days to three

Skills

Studies: ETAP (load flow, short circuit, protection coordination, arc flash), cable and earthing calculations

Design: single-line diagrams, schematics, AutoCAD Electrical, switchgear and transformer specifications

Testing: relay secondary injection (Omicron test sets), insulation resistance, FAT and SAT procedures

Standards: IEC switchgear and installation standards, IEEE 1584, utility connection requirements

Registration and training

Graduate engineer registration (electrical)

National board of engineers

2021

High-voltage switching and safety course

Accredited training provider

2023

Education

BEng (Hons) Electrical Power Engineering

Seraya Hills University of Technology, Selangor

2016 – 2020

Final-year project: overcurrent relay coordination on a radial 11 kV feeder with embedded solar generation

Languages

  • Malay (native)
  • English (fluent)
  • Mandarin (basic)

Open this example in the resume builder Start empty with this template

Why this resume works

  • Ratings run through the whole page: 33 kV, 11 kV, 30 MWac, 4,000 A, 50 kA. In power engineering these figures define the work, and they tell a reader immediately that her field is medium- and low-voltage distribution, not transmission or electronics.
  • The studies bullet lists three study types and the protection functions she set (overcurrent, earth fault, transformer differential). A protection engineer can gauge her depth from that, where the single word "ETAP" would leave them guessing.
  • One line records a problem caught on paper: a board rated 50 kA where the calculated fault level was 58 kA. It shows what a short-circuit study is for and that she acted on the answer.
  • Commissioning is written in the language of test sheets: secondary injection, insulation resistance, CT ratio and polarity, interlocks. Anyone who has stood in a substation recognises the sequence and can ask about it at interview.
  • The switchgear factory role explains her practical grounding, with 80 boards drawn and tests run in front of client inspectors, and the registration section states honestly where she is on the route to professional status.

What employers look for in this role

  • Design power distribution systems: single-line diagrams, cable sizing, earthing, and switchgear and transformer specifications
  • Carry out load-flow, short-circuit, protection coordination and arc-flash studies, and issue relay settings
  • Produce schematics, wiring diagrams, cable schedules and equipment layouts
  • Check designs against IEC, IEEE or national standards and the utility's connection requirements
  • Witness factory acceptance tests and lead or support site testing and commissioning
  • Review vendor drawings and technical bids, and answer contractor queries during installation
  • Prepare test reports, as-built drawings and operating documents for handover

Skills to consider

List only the skills you can back up with an example. These are the ones that come up most for this kind of role.

Power system studies
Load flow and voltage drop, Short-circuit calculation, Protection coordination and relay settings, Arc-flash analysis, Harmonic and motor-starting studies, ETAP, DIgSILENT PowerFactory or SKM
Design and documentation
Single-line diagrams, Schematics and wiring diagrams, AutoCAD Electrical or EPLAN, Cable sizing and schedules, Earthing and lightning protection, Equipment specifications and datasheets
Testing and commissioning
Relay secondary injection, Primary injection and CT testing, Insulation resistance and high-voltage testing, Factory and site acceptance tests, Switching procedures and permits to work, PLC and SCADA point-to-point checks
Standards and safety
IEC and IEEE standards, National wiring regulations, Utility grid connection requirements, Electrical safety rules and isolation

More bullet points to adapt

Each of these follows the same pattern as the example: an action, what it was applied to, and what changed. Swap in your own facts and figures. The bullet builder assembles the pattern for you.

  • Sized and specified two 2,500 kVA cast-resin transformers and an 11 kV ring main unit for a hospital extension, with N-1 redundancy on the essential supply
  • Corrected a grading error between a feeder relay and a downstream fuse, restoring a 0.3-second margin and ending nuisance trips on a compressor feeder
  • Modelled the start of a 1.2 MW pump motor and specified a soft starter that kept voltage dip at the 11 kV bus below 8%
  • Wrote the site acceptance test procedure for a 24-panel 11 kV switchboard and directed a five-day test programme with the utility witness present
  • Lowered copper cost on a feeder schedule by 12% by recalculating cable sizes from measured load data in place of nameplate ratings
  • Mapped 340 IEC 61850 GOOSE and SCADA signals for a substation automation upgrade and verified each one point to point during commissioning

Words that recur in adverts

These terms appear often in adverts for this kind of role. Use the ones that are true of you, in sentences that show the skill in use, and check a specific advert with the keyword checker.

  • Single-line diagram
  • Protection coordination
  • Short-circuit study
  • Load flow
  • Arc flash
  • Medium voltage
  • Switchgear
  • Relay settings
  • Schematics
  • ETAP
  • IEC standards
  • Commissioning
  • Factory acceptance test (FAT)
  • Earthing

Which sections to include

State your specialism and voltage range in the headline and summary: "electrical engineer" covers power, controls and electronics, and employers hire for one of them. Experience follows, with study and design work first in each role and testing or commissioning after it, every item carrying a rating or an equipment count. Put skills next and split them into studies, design, testing and standards, naming only software you can drive unaided. Registration and safety training come after that, because access to site often depends on them. Education closes the page. A final-year project earns a line for the first few years if it matches your specialism, and can go later.

Mistakes to avoid

  • Calling yourself an electrical engineer with no voltage level or sector. Say whether your work is low, medium or high voltage, and whether it is utility, industrial, building services or renewables.
  • Naming a study package without the studies. "Proficient in ETAP" says little, so list the study types you have run, for how many sites, and what the results changed in the design.
  • Summing up commissioning as "attended site". State the tests you performed or witnessed, the equipment involved and whether you were responsible for accepting the results.
  • Mixing power, controls and electronics tools in one long list. Someone hiring for protection work gains nothing from PCB layout software, so keep the list to your specialism and the advert.
  • Leaving out safety training and authorisations. If you hold a switching authorisation or site safety certificates, list them with dates, since they affect how soon you can work on live sites.

Questions and answers

Should I list the electrical standards I work to?

Name the families you use every day, such as IEC switchgear and installation standards or IEEE 1584 for arc flash, plus any the advert names that you have applied. Wiring regulations and utility rules differ between countries, so do not imply knowledge of local rules you have not used. The guide to resume keywords covers matching an advert's wording honestly.

How do I describe study or protection work without revealing client information?

Give the scope and leave out the identity. The number of sites, the voltage levels, the study types and what changed as a result are all safe to state, as "a food plant" is here. Leave out site names, relay settings and anything from a single-line diagram that would identify the installation.

I work in industrial controls, not power. Can I still follow this example?

Yes: keep the structure and change the vocabulary. Replace study types with PLC and HMI platforms, I/O counts, drives and safety circuits, and replace relay testing with loop checks, factory acceptance tests and start-up support. The same test applies to each bullet: it should give the size of the system and what you personally designed, programmed or tested.

How do I show that I am working towards professional registration?

Add one line under certifications giving your current grade, and say in the summary that you are working towards the next. Leave out a predicted date unless your assessment is booked. Routes and titles differ by country, so use the wording of your own registration body, and let your bullets show the responsibility you already carry.