The formula
P = V × I
Variables and units
| Symbol | Meaning | Unit |
|---|---|---|
| P | power | watts (W) |
| V | voltage across the load | volts (V) |
| I | current through the load | amperes (A) |
Other forms of the formula
The same relationship rearranged, so you can solve for whichever quantity is unknown.
- I = P ÷ V
- V = P ÷ I
- P = I² × R
- P = V² ÷ R
How it works
Voltage is energy per unit of charge and current is charge per second, so their product is energy per second. Combined with Ohm's law, the same power can be written P = I² × R or P = V² ÷ R.
For AC circuits with motors or other reactive loads, real power is V × I × power factor. The plain product V × I is then the apparent power in volt-amperes.
Worked example
A heater draws 8 A from a 230 V supply. What is its power?
- P = 230 V × 8 A
- P = 1,840 W
1.84 kW. Run for 3 hours, it uses 5.52 kWh.
Common mistakes
- Ignoring power factor for motors and other inductive AC loads.
- Mixing milliamperes with volts without converting to amperes.
Where it is used
Choosing fuses, cables and power supplies, and estimating running costs.
Frequently asked questions
What is the formula for electrical power?
P = V × I. Rearranged to find the other quantities: I = P ÷ V; V = P ÷ I; P = I² × R.
What do the symbols mean, and which units should I use?
P is power (watts (W)); V is voltage across the load (volts (V)); I is current through the load (amperes (A)). Use consistent units so the answer comes out in the unit you expect.
What are common mistakes with this formula?
Ignoring power factor for motors and other inductive AC loads. Mixing milliamperes with volts without converting to amperes.
Where is this formula used?
Choosing fuses, cables and power supplies, and estimating running costs.
Is there a worked example?
Yes. A heater draws 8 A from a 230 V supply. What is its power? 1.84 kW. Run for 3 hours, it uses 5.52 kWh.